Anyone seen USB redirection issues with CWA 2203 CU2 in Windows 10? We rolled out to out VDI desktops which are accessed via thin clients and had random issues of USB passthrough not working. On some VDI desktops had issues with the Citrix Redirection Service not running. Others showed USB Redirection Virtual Channel errors. The odd thing was, we saw no issues during our initial testing, the issues started to show randomly ~2.5 weeks later across a pool of ~1200 desktops. We had 3 days in a row of issues happening sporadically across different physical sites. Issues also were not necessarily seen first thing in the AM and were reported at different times during the day. Almost like a service was crashing causing USB redirection to break mid-day. We reboot all desktops nightly. Even though the timing of the change the vdisk did not align with when issues started, there had been no other changes we could think of that would be causing the issues. Sure enough, we are about 1 week post vdisk rollback (CWA 1912 CU5) and have had no further issues.