Running 2407 and 2411 and getting picadm.sys BSOD's again - anyone else seeing these issues?
s
Steve Noel
02/06/2025, 9:03 PM
I haven't, running 2411 VDA on 2025 (vmware).
m
Mike Compton
02/06/2025, 9:24 PM
We are running Openstack. I do have a 2025 server that has not had any issue yet. I have 30 servers running a mix of 2019, and 2022 and have experienced BSODs on all of them with 2407/11
Thanks, I found that as well - going to open a ticket now for fun.
d
Danny
02/07/2025, 1:52 PM
long shot btu check if HDX direct is enabled
r
Rody Kossen
02/08/2025, 7:24 PM
@Mike Compton do you have a memory dump? If so, can you create a support case and upload the dump?
Can you then share the case number? ( I work at Citrix engineering)