Hello, I'm having some trouble with the octavia-cl...
# replication-troubleshooting
j
Hello, I'm having some trouble with the octavia-cli. I'm trying to run the command:
Copy code
octavia --airbyte-url <http://localhost:8500> get connection <CONNECTION_ID>
but end up getting the following error:
Copy code
TypeError: _from_openapi_data() missing 3 required positional arguments: 'schema_change', 'notify_schema_changes', and 'non_breaking_changes_preference'
This does not occur when trying to get a source or destination. Any help is greatly appreciated. Thanks!
m
j
Hi Marcos! Thanks for the reply + thread. It turns out that the version of octavia was not the same as the version of airbyte. Once they were the same the issue resolved! thanks
n
Good to hear this was resolved! Thank you @Marcos Marx (Airbyte) 😊