07/01/2025, 2:14 PMHi Jon,
The final install string will need to be modified to remove that NO_START flag. I've linked the documentation for recommended steps to create the VDI image which recommends the following:
Copy code<installer_filename> /install CID=<CCID> VDI=1
https://falcon.us-2.crowdstrike.com/documentation/page/ecc97e75/falcon-sensor-for-windows-deployment#paf4c833
The VDI flag will prevent the sensor from assigning a unique sensor ID to the host (which would then be incorrectly propagated to other hosts running that baseline), however the template system will need to have the sensor running, ideally at least 30 minutes, to ensure it has time to connect to the cloud and pull down whatever updated config is pending.