This message was deleted.
# citrix-vad
s
This message was deleted.
o
VDA and CWA at very recent versions? I wouldnt think Rendezvous 2.0 would matter, but the VDA has to be 2303 I think or higher - something like that -same with very new CWA requirements. I have been enabling now, but most times still relying on Direct Workload Connection with CWA/VDAs needing to be very recent for this to do it's thing for anybody needing to use it. I will have to check one next time while disabling Direct Workload Connection and see if it figures it out and connects directly..
j
I'm running the latest of both the VDA and CWA obviously. Also yes I have disabled Direct Workload Connection prior to testing.
o
Why obviously mate? Is that something I should just assume then? That sort of response dampens me wanting to help at all as I guess it should be obvious of what you have done or not done and I will magically just know. good luck
I was going to go look at my working situation, but I should just assume you have everything right so no point to ask questions
j
I meant no disrespect Scott but since the feature is in tech preview, it goes without saying I have installed the latest of everything.
o
Have seen all things in this WOEUC and one is that not everybody knows every detail which is why we ask questions. I guess to that thought for everybody in here that is asking about a feature, I just assume they know what is tech preview and what isn't and have updated all their other components accordingly? Have been here long enough to know that just because a feature is tech preview, not everybody asking about the many many features I test know about all the pre-reqs when testing said feature. Obviously
j
I'm running Citrix DAAS with Azure machine with Windows 11 22h2 with VDA 2305. I tested Workspace App 2307 and 2309 TP on Windows endpoints. CWA 2309 seem to break UDP connection so I'll be rolling back to 2307.
I'll also test VDA 2308 once it gets released. Maybe this feature will be GA.
r
@Jonathan Pitre Just to confirm, the client & VDA have direct line of sight? No ports are being blocked? (TCP & UDP 443) If there is direct line of sight and no blocked ports, I would suggest creating a CDF trace on both client and VDA and open up a support case. With the trace we can figure out what is going on. Also, what is the issue you are seeing with CWA 2309 TP? Can you DM me some details?
👍 1
j
Rendezvous is for the vda to bypass the cloud connectors to connect to the citrix cloud control plane. Network locations in citrix cloud enable you to specify “internal” public IPs where users connecting from an endpoint behind that ip will be connected directly to the via rather than passed through the gateway service. https://docs.citrix.com/en-us/citrix-workspace/optimize-cvad/workspace-network-location.html
Sorry, misunderstood. HDX Direct allows connections over tcp/udp 443 rather than 2598.