Can confirm sst performs nearly identically as std ke even in fairly complex flows with rotation, curvature, and separation (away from the wall). Omega mode activates very close to walls, infact to an extent where it's practically just k epsilon if you keep a coarse y+ and wall functions.
What
@timbuk21004 suggested about exercising more control over blending the coefficients - I think that's the general idea behind GEKO models. I quote:
``
The key
to such a strategy is the provision of free parameters which the user can adjust for specific types of
applications without negative impact on the basic calibration of the model.``
https://www.ansys.com/content/dam/amp/2022/march/quick-request/Best-Practice-GEKO-Turbulence-Modeling-in-Ansys-CFD.pdf