:red_circle: HIGH SEV 路 Inference Proxy Producer S...
# alarms-prod
a
馃敶 HIGH SEV 路 Inference Proxy Producer Silent (ozone-proxy stopped sending events) 馃敟 ozone-proxy has stopped producing packets to device-events <|馃搱 graph> 路 <|馃搳 service dashboard> 路 馃毃 alarm definition 路 馃敃 silence _HIGH SEV - permanent loss. Closes the CLE-456 gap on the proxy side. The aggregate 'Consumer Starved' rule cannot see this: if the proxy dies while ozone-api keeps producing, total intake stays non-zero and nothing fires. That is exactly the 2026-07-14 outage, which ran ~1.5 days unnoticed. When the proxy stops, foreground detection stops: screen time stops accruing, limits never trigger, and kids silently get unlimited access. The events were never produced, so there is NO backfill - that time is permanently unaccounted. Uses kind="packets" as the liveness signal. Do NOT use kind="block_event": it is legitimately 0 for long stretches because blocks are rare. Prod baseline ~12.8 packets/s. no_data=Alerting on purpose - an absent produce metric is itself the failure signal (the metric only exports after the first produce)._ Grafana vmain-b1e6358