I'm trying to collect operator-level metrics from ...
# troubleshooting
d
I'm trying to collect operator-level metrics from Flink jobs, but it looks like nothing shows up if the whole job runs with parallelism 1 (meaning it's just using a single task manager, as I understand it, with no serialization between operator steps) - not even application-level metrics. Is this a known issue, and is there any way around it (short of creating an artificial parallelism difference just to split it into chunks)?
p
Hello there, Dennis. How does your Flink graph looks like? Sometimes flink may merge operators. To disable that you can check disable chaining. Or perhaps I did not understand the problem itself 😅
d
yes, the Flink graph is a single box in these cases. If we disable chaining, will that incur a substantial performance hit?
p
I'd not say substantial. If you're not using Kryo, I'd say you won't notice it.