Prathmesh Sidana
11/11/2024, 6:49 AMCaused by: java.util.concurrent.CompletionException: java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner.
Did you change the partitioner to forward or rescale?
It may also help to add an explicit shuffle().
at org.apache.flink.runtime.scheduler.adaptive.BackgroundTask.lambda$new$0(BackgroundTask.java:59) ~[flink-dist-1.19.0.jar:1.19.0]
at java.util.concurrent.CompletableFuture$UniApply.tryFire(Unknown Source) ~[?:?]
at java.util.concurrent.CompletableFuture$Completion.run(Unknown Source) ~[?:?]
at java.util.concurrent.ThreadPoolExecutor.runWorker(Unknown Source) ~[?:?]
at java.util.concurrent.ThreadPoolExecutor$Worker.run(Unknown Source) ~[?:?]
at java.lang.Thread.run(Unknown Source) ~[?:?]
Caused by: java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner.
Did you change the partitioner to forward or rescale?
It may also help to add an explicit shuffle().
Please help herePrathmesh Sidana
11/12/2024, 4:35 PMPrathmesh Sidana
11/12/2024, 4:35 PMMaxim Senin
11/12/2024, 7:21 PMMaxim Senin
11/12/2024, 7:26 PMPrathmesh Sidana
11/13/2024, 4:16 AMMaxim Senin
11/13/2024, 7:28 PMjava.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner. in the context of Apache Flink typically arises when you're trying to rescale an operator that uses a pointwise partitioner (such as a keyed or partitioned operator) in a way that is not supported by Flink.
### Understanding the Issue
In Flink, when you use a partitioner (e.g., keyBy, rebalance, rescale, etc.), the partitioning defines how data is distributed across tasks (parallel instances of operators). A pointwise partitioner means that each input element is sent to a specific partition based on its value (for instance, key-based partitioning in keyBy).
The rescale operation in Flink is designed to adjust the parallelism of operators while redistributing the data between tasks. However, pointwise partitioning can be a problem in this context because:
- Flink cannot automatically figure out how to redistribute the data in a way that respects the original pointwise partitioning logic.
- Some partitioning strategies are inherently tied to the original parallelism and cannot be changed dynamically (e.g., keyBy partitions data based on the key, and adjusting parallelism would require redistributing the keys).
### Typical Scenario for This Error
This error typically occurs when you try to:
1. Rescale a keyed stream (e.g., after using keyBy) or any operator that uses a pointwise partitioner like rebalance or broadcast.
2. Change the parallelism of an operator that requires maintaining the partitioning scheme in a way that rescaling can't handle automatically.
### Solutions
Here are some common approaches to handle this issue:
#### 1. Avoid Rescaling on Keyed Operators
If the operator is keyed (using keyBy), Flink will not be able to rescale it because the partitioning is based on the key, and rescaling could violate this partitioning. You can try to avoid rescaling on keyed operators, or, if absolutely necessary, use a different approach to change the parallelism:
- Repartition the stream before applying the rescale:
java
DataStreamMyType inputStream = ...;
// Example: First, shuffle or rebalance the data
inputStream = inputStream.rebalance(); // or use other partitioners like 'shuffle', 'rescale'
// Then, apply the keyBy operation
inputStream.keyBy(...);
#### 2. Rescale Non-Keyed Streams
If you're working with a non-keyed stream (e.g., after using an operator that doesn't involve key-based partitioning), then you can rescale the stream without encountering this issue. For example:
- Rescale without keyBy:
java
DataStreamMyType inputStream = ...;
// Apply rescale without keyBy
inputStream = inputStream.rescale();
// Then apply further operators
inputStream.map(...);
#### 3. Explicitly Set Parallelism
In some cases, if you're facing issues with rescaling, you can manually set the parallelism for operators before applying any partitioning or rescaling.
java
DataStreamMyType inputStream = ...;
inputStream
.setParallelism(4) // Set explicit parallelism
.keyBy(...);
Setting the parallelism explicitly before applying the partitioning might help prevent issues related to rescaling, as you can control the partitioning strategy better.
#### 4. Using rebalance instead of rescale
If you're trying to apply rescaling after a keyBy, a possible workaround is to use rebalance instead of rescale for partitioning:
java
DataStreamMyType inputStream = ...;
inputStream = inputStream.rebalance(); // Rebalance instead of rescaling
inputStream.keyBy(...);
This would distribute the records evenly across the available operators, but it might not guarantee the same behavior as keyBy.
#### 5. Check for Incompatible Operations
Some partitioning schemes are incompatible with certain operations. If you try to apply operations like rescale to an operator that involves incompatible partitioning, Flink may throw this exception.
#### 6. Change the Operator Flow
If you really need to change the parallelism dynamically, consider reordering your operations. Apply operations like rebalance, broadcast, or rescale before you apply keyBy, which could eliminate the partitioning dependency.
### Summary
The error java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner usually indicates that you're trying to rescale an operator that involves partitioning, such as a keyed stream. To fix this:
- Avoid rescaling after a keyBy or any operator that uses a pointwise partitioner.
- Consider rebalance or shuffle the stream before applying keyBy.
- Use explicit parallelism instead of rescaling when working with partitioned data.
If you need to rescale a stream that has been partitioned in a particular way (especially by key), make sure the partitioning operation is applied after the rescaling operation, or use other operators that are more compatible with dynamic rescaling.Prathmesh Sidana
11/14/2024, 1:33 AM