Hi all, I want to enable autoscaling in my flink j...
# troubleshooting
p
Hi all, I want to enable autoscaling in my flink job with version 1.19. But getting this error Is there a way I can change partitioner configuration ?
Copy code
Caused by: java.util.concurrent.CompletionException: java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner.
Did you change the partitioner to forward or rescale?
It may also help to add an explicit shuffle().
	at org.apache.flink.runtime.scheduler.adaptive.BackgroundTask.lambda$new$0(BackgroundTask.java:59) ~[flink-dist-1.19.0.jar:1.19.0]
	at java.util.concurrent.CompletableFuture$UniApply.tryFire(Unknown Source) ~[?:?]
	at java.util.concurrent.CompletableFuture$Completion.run(Unknown Source) ~[?:?]
	at java.util.concurrent.ThreadPoolExecutor.runWorker(Unknown Source) ~[?:?]
	at java.util.concurrent.ThreadPoolExecutor$Worker.run(Unknown Source) ~[?:?]
	at java.lang.Thread.run(Unknown Source) ~[?:?]
Caused by: java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner.
Did you change the partitioner to forward or rescale?
It may also help to add an explicit shuffle().
Please help here
Can someone help here please??
...
m
I could not get any help with this since May lol
But the gist of it is you're either a) using a partitioner that doesn't support rescaling - use proper partitioner b) checkpointing fails which results in inability to restore state during rescaling. Had to disable unaligned checkpoints for the latter. Basically for some unknown reason flink is unable to rescale because it can't redistribute checkpoint data when there's any inflight data, so by disabling unaligned checkpoints we seem to have eliminated the cause of the crash.
p
Can you tell how can I change my partitioner?
m
The error message
java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner.
in the context of Apache Flink typically arises when you're trying to rescale an operator that uses a pointwise partitioner (such as a keyed or partitioned operator) in a way that is not supported by Flink. ### Understanding the Issue In Flink, when you use a partitioner (e.g.,
keyBy
,
rebalance
,
rescale
, etc.), the partitioning defines how data is distributed across tasks (parallel instances of operators). A pointwise partitioner means that each input element is sent to a specific partition based on its value (for instance, key-based partitioning in
keyBy
). The rescale operation in Flink is designed to adjust the parallelism of operators while redistributing the data between tasks. However, pointwise partitioning can be a problem in this context because: - Flink cannot automatically figure out how to redistribute the data in a way that respects the original pointwise partitioning logic. - Some partitioning strategies are inherently tied to the original parallelism and cannot be changed dynamically (e.g.,
keyBy
partitions data based on the key, and adjusting parallelism would require redistributing the keys). ### Typical Scenario for This Error This error typically occurs when you try to: 1. Rescale a keyed stream (e.g., after using
keyBy
) or any operator that uses a pointwise partitioner like
rebalance
or
broadcast
. 2. Change the parallelism of an operator that requires maintaining the partitioning scheme in a way that rescaling can't handle automatically. ### Solutions Here are some common approaches to handle this issue: #### 1. Avoid Rescaling on Keyed Operators If the operator is keyed (using
keyBy
), Flink will not be able to rescale it because the partitioning is based on the key, and rescaling could violate this partitioning. You can try to avoid rescaling on keyed operators, or, if absolutely necessary, use a different approach to change the parallelism: - Repartition the stream before applying the rescale:
Copy code
java
    DataStreamMyType inputStream = ...;

    // Example: First, shuffle or rebalance the data
    inputStream = inputStream.rebalance();  // or use other partitioners like 'shuffle', 'rescale'

    // Then, apply the keyBy operation
    inputStream.keyBy(...);
#### 2. Rescale Non-Keyed Streams If you're working with a non-keyed stream (e.g., after using an operator that doesn't involve key-based partitioning), then you can rescale the stream without encountering this issue. For example: - Rescale without
keyBy
:
Copy code
java
    DataStreamMyType inputStream = ...;

    // Apply rescale without keyBy
    inputStream = inputStream.rescale();

    // Then apply further operators
    inputStream.map(...);
#### 3. Explicitly Set Parallelism In some cases, if you're facing issues with rescaling, you can manually set the parallelism for operators before applying any partitioning or rescaling.
Copy code
java
DataStreamMyType inputStream = ...;

inputStream
    .setParallelism(4)  // Set explicit parallelism
    .keyBy(...);
Setting the parallelism explicitly before applying the partitioning might help prevent issues related to rescaling, as you can control the partitioning strategy better. #### 4. Using
rebalance
instead of
rescale
If you're trying to apply rescaling after a
keyBy
, a possible workaround is to use
rebalance
instead of
rescale
for partitioning:
Copy code
java
DataStreamMyType inputStream = ...;

inputStream = inputStream.rebalance();  // Rebalance instead of rescaling
inputStream.keyBy(...);
This would distribute the records evenly across the available operators, but it might not guarantee the same behavior as
keyBy
. #### 5. Check for Incompatible Operations Some partitioning schemes are incompatible with certain operations. If you try to apply operations like
rescale
to an operator that involves incompatible partitioning, Flink may throw this exception. #### 6. Change the Operator Flow If you really need to change the parallelism dynamically, consider reordering your operations. Apply operations like
rebalance
,
broadcast
, or
rescale
before you apply
keyBy
, which could eliminate the partitioning dependency. ### Summary The error
java.lang.UnsupportedOperationException: Cannot rescale the given pointwise partitioner
usually indicates that you're trying to rescale an operator that involves partitioning, such as a keyed stream. To fix this: - Avoid rescaling after a
keyBy
or any operator that uses a pointwise partitioner. - Consider rebalance or shuffle the stream before applying
keyBy
. - Use explicit parallelism instead of rescaling when working with partitioned data. If you need to rescale a stream that has been partitioned in a particular way (especially by key), make sure the partitioning operation is applied after the rescaling operation, or use other operators that are more compatible with dynamic rescaling.
p
OK will explore these approaches, Thanks