Nishant Goenka
07/15/2024, 7:14 AMakka.remote.OversizedPayloadException: Discarding oversized payload sent to Actor[akka.tcp://flink@10.220.51.56:6122/user/rpc/taskmanager_0#1423510823]: max allowed size 10485760 bytes, actual size of encoded class org.apache.flink.runtime.rpc.messages.RemoteRpcInvocation was 14835748 bytes.
After above issue I started getting this exception,
ERROR akka.remote.EndpointWriter [] - Transient association error (association remains live)
Later, what I saw Flink job was in restarting mode for few hours, until i went and manually killed the job to do so, FYI I am using flink 1.19.0
Any help would be really helpful, so that same wont get repeated in future.
Thanks in advance.Flavio V.
07/15/2024, 3:39 PMNishant Goenka
07/15/2024, 4:19 PMpekko.ask.timeout: 600s
pekko.client.timeout: 600s
pekko.framesize: "16835800b"Nishant Goenka
07/16/2024, 5:28 AM