David Bryson
03/07/2024, 7:15 PMselect observed_at, measurement from database;
observed_at | measurement
------------------------+-------------
2024-03-04 09:49:00+00 | -904
2024-03-04 09:54:00+00 | -906
2024-03-04 09:59:00+00 | -905
2024-03-04 10:04:00+00 | -905
2024-03-04 10:09:00+00 | -907
2024-03-04 10:14:00+00 | -903
2024-03-04 10:19:00+00 | -907
2024-03-04 10:24:00+00 | -905
2023-10-14 00:01:00+00 | -912
2023-10-14 00:06:00+00 | -910
2023-10-14 00:11:00+00 | -914
2023-10-14 00:16:00+00 | -910
When I use this table as my source for a datastream I get the data in this sequence, which of course is not in order. If I add an ordering section ORDER BY observed_at ASC in a regular postgres query then the order is as expected. When I do this in Flink it reads and processes 745 records(out of 42000), all within the timeframe of 2024-03-04, and none of the earlier data. This is extremely confusing behavior, am I missing something obvious like the read size of the JDBC query? Should I even be using this connector for this kind of usecase? I feel like I"m missing something obvious here.David Bryson
03/07/2024, 7:59 PM