<@U04S8PLJWMT> sudden issue with mysql source dupl...
# ask-ai
g
@kapa.ai sudden issue with mysql source duplications replication-orchestrator INFO failures: [ { "failureOrigin" : "replication", "internalMessage" : "No exit code found.", "externalMessage" : "Something went wrong during replication", "metadata" : { "attemptNumber" : 0, "jobId" : 8811 }, "stacktrace" : "java.lang.IllegalStateException: No exit code found.\n\tat io.airbyte.workers.internal.ContainerIOHandle.getExitCode(ContainerIOHandle.kt:104)\n\tat io.airbyte.workers.internal.LocalContainerAirbyteDestination.getExitValue(LocalContainerAirbyteDestination.kt:117)\n\tat io.airbyte.workers.general.BufferedReplicationWorker.readFromDestination(BufferedReplicationWorker.java:495)\n\tat io.airbyte.workers.general.BufferedReplicationWorker.lambda$runAsync$2(BufferedReplicationWorker.java:215)\n\tat java.base/java.util.concurrent.CompletableFuture$AsyncRun.run(CompletableFuture.java:1804)\n\tat java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1144)\n\tat java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:642)\n\tat java.base/java.lang.Thread.run(Thread.java:1583)\n",
k
There are several reports of sudden issues with MySQL source duplications or sync failures in Airbyte, especially when using incremental or CDC (Change Data Capture) sync modes. Based on the knowledge sources, here are some common causes and troubleshooting steps: 1. Schema Changes and Binlog Issues If the schema of your MySQL tables changes (e.g., columns added/removed), Airbyte's CDC process can fail or behave unexpectedly, sometimes requiring a schema refresh or a full reset of the connection. Errors like "different column size with internal schema size" or "changes were detected on an unknown table" are typical symptoms. This can lead to duplicate or missing records if not handled properly. It's recommended to refresh your schema or reset the connection when such changes are detected. Also, check MySQL binlog settings, such as
log_bin_use_v1_row_events
, as certain configurations can cause CDC to break or duplicate data. Setting this variable to
OFF
has resolved issues for some users. [MySQL CDC Issue - Debezium error](https://github.com/airbytehq/airbyte/issues/51607) 2. Binlog Retention and Expiry If MySQL purges binlogs before Airbyte can process them (due to low
binlog_expire_logs_seconds
or similar settings), Airbyte may be forced to do a full refresh, which can result in duplicate data if the destination is not properly deduplicated. Increasing binlog retention can help prevent this. [MySQL Troubleshooting](https://docs.airbyte.com/integrations/sources/mysql/mysql-troubleshooting#troubleshooting) 3. Connector Bugs or Configuration Issues There have been bugs where duplicate configuration fields or improper handling of sync modes caused issues. For example, a duplicate "Configured server timezone" field was reported and fixed in a recent connector update. [Connector configuration duplicate attributes](https://github.com/airbytehq/airbyte/issues/52141) 4. MariaDB and MySQL Compatibility If you are using MariaDB as a source with the MySQL connector, there are known limitations, especially with CDC. This can result in unexpected errors or duplications. If you encounter issues, consider switching to a different replication method. [MariaDB CDC limitations](https://docs.airbyte.com/integrations/sources/mysql/mysql-troubleshooting#troubleshooting-mysql-sources) 5. Sudden Failures After Successful Syncs Some users have reported that after a period of successful syncs, connections suddenly start failing or duplicating data. This can be due to changes in the source schema, binlog purging, or resource constraints. Reviewing logs for errors related to binlog position, schema mismatch, or timeouts can help pinpoint the issue. [Forum: Suddenly after two days some of the syncs are failing](https://discuss.airbyte.io/t/2656) Summary: Sudden duplication issues with the MySQL source in Airbyte are often related to schema changes, binlog retention, or connector configuration. Review your MySQL binlog settings, ensure your schema is up to date in Airbyte, and check for any recent connector updates or known bugs. If using MariaDB, be aware of CDC limitations. If the problem persists, resetting the connection or increasing binlog retention may help. If you have specific error messages or logs, sharing them can help narrow down the root cause further.
The error message you provided—`"No exit code found."` with a stack trace involving
ContainerIOHandle.getExitCode
and `LocalContainerAirbyteDestination.getExitValue`—is a known issue in Airbyte that can occur during replication jobs, including those involving MySQL sources. This error typically indicates that the Airbyte worker process was unable to retrieve the exit code from the destination container, often because the process terminated unexpectedly or the container was already closed when the system tried to access its exit code. This can be triggered by a variety of underlying issues, such as: - The destination process (or sometimes the source) closing prematurely or crashing. - The Airbyte platform or connector version incompatibilities. - Resource constraints or unexpected termination of the container. Several similar issues have been reported for different connectors and sources, including MySQL, Snowflake, BigQuery, and Postgres. In these cases, the logs often show that the process was already closed or that the exit code file could not be found, leading to this error message. For example, in the context of a Snowflake source, it was noted that "the connection is closing prematurely," which results in the "No exit code found" error when Airbyte tries to close an already closed connection. This pattern is consistent across other connectors as well, including MySQL sources and destinations [source-snowflake reporting "No exit code found."](https://github.com/airbytehq/airbyte/issues/56456), [destination-postgres different registry doesn't work](https://github.com/airbytehq/airbyte/issues/54691). If you are experiencing sudden duplications or failures with your MySQL source and see this error, it is likely related to the premature closure or crash of the connector process. The knowledge sources do not provide a definitive root cause or a universal fix, but they suggest checking for: - Recent changes in connector or platform versions. - Resource constraints on your Airbyte deployment. - Any logs indicating why the connector process might be terminating unexpectedly. If the issue persists, consider rolling back to a previous connector version or reviewing recent changes in your environment. If you need further assistance, providing more detailed logs or opening an issue on the Airbyte GitHub repository may help the community or maintainers diagnose the problem more specifically. I'm sorry, but the knowledge sources do not contain a specific solution for MySQL source duplications related to this error. The general guidance above is based on similar reported issues across connectors.
g
@kapa.ai can see this in the logs Failed to wait for exit value file /dest/exitCode.txt to be found.
k
A message from kapa.ai
The error message
Failed to wait for exit value file /dest/exitCode.txt to be found.
indicates that Airbyte was unable to locate the
exitCode.txt
file, which is used to determine the exit status of a connector process (source or destination). This file is expected to be written by the connector container when it finishes execution. This issue is commonly associated with the following scenarios: - Connector or Platform Version Mismatch: If you are using a connector version that requires a newer Airbyte platform version, the connector may not write the
exitCode.txt
file as expected, leading to this error. For example, with the BigQuery destination, the logs explicitly state: > "You must upgrade your platform version to use this connector version. Either downgrade your connector or upgrade platform to 0.63.7" This means the connector expects platform features that are not present in your current Airbyte deployment, resulting in failures to write/read the exit code file and subsequent sync failures [Github Issue: destination-bigquery](https://github.com/airbytehq/airbyte/issues/59702). - Timeouts or Premature Container Termination: If the connector container crashes, is killed, or times out before it can write the
exitCode.txt
file, Airbyte will not be able to find it and will throw this error. This can be due to resource constraints, misconfiguration, or bugs in the connector or platform [Github Issue: destination-postgres](https://github.com/airbytehq/airbyte/issues/54691). Recommended Actions: 1. Check Connector and Platform Compatibility: Ensure that your connector version is compatible with your Airbyte platform version. If you see a message about upgrading or downgrading, follow that advice. 2. Review Resource Limits: Make sure your environment provides enough resources (CPU, memory) for the connector containers to complete their work. 3. Check for Container Crashes: Look for other errors in the logs that might indicate why the connector process did not finish cleanly. 4. Upgrade/Downgrade as Needed: If you recently upgraded a connector, try downgrading it or upgrading your Airbyte platform to the recommended version. If you need more specific troubleshooting, please provide additional context or logs from the sync attempt. For more details, see the related discussion and error logs: [Github Issue: destination-bigquery](https://github.com/airbytehq/airbyte/issues/59702) [Github Issue: destination-postgres](https://github.com/airbytehq/airbyte/issues/54691)
g
@kapa.ai Attempted to close a destination which is already closed. Write to destination failed — exiting read dest... Using redshift destincation
k
A message from kapa.ai
The error message "Attempted to close a destination which is already closed. Write to destination failed — exiting read dest..." when using the Redshift destination in Airbyte typically indicates that the destination connector process encountered a failure and was closed (either due to an error or a crash), but another part of the system tried to close it again or continue writing, resulting in this warning or error. From the knowledge sources, similar issues have been observed when: - The Redshift destination connector fails due to connection issues, such as
[Amazon](500150) Error setting/closing connection: Connection refused
or
HikariPool-1 - Connection is not available, request timed out after 60002ms
. These errors cause the connector to terminate unexpectedly, which can lead to the "already closed" message when Airbyte tries to perform cleanup or further operations on the closed connector [Destination Redshift: destination does not abort sync on runtime error](https://github.com/airbytehq/airbyte/issues/26821). - There are network or resource issues that prevent the Redshift connector from maintaining a stable connection, leading to abrupt termination and subsequent errors during shutdown or cleanup. What you can do: - Check the logs for preceding errors, especially those related to Redshift connectivity or timeouts. - Ensure that your Redshift instance is reachable from your Airbyte deployment and that there are no network/firewall issues. - Review your resource allocation (CPU, memory) for the Airbyte worker pods/containers, as resource exhaustion can cause premature connector termination. - If you see repeated connection errors, consider increasing connection pool settings or reviewing Redshift's connection limits. If the problem persists, providing the full error stack trace or additional log context can help further diagnose the root cause. This behavior is consistent with the issues described in the knowledge sources, where connection failures or abrupt connector termination lead to cleanup errors and "already closed" warnings [Destination Redshift: destination does not abort sync on runtime error](https://github.com/airbytehq/airbyte/issues/26821).
g
@kapa.ai what is this error [ { "failureOrigin" : "replication", "internalMessage" : "Broken pipe", "externalMessage" : "Something went wrong during replication", "metadata" : { "attemptNumber" : 0, "jobId" : 8831 },
k
A message from kapa.ai
The error message:
Copy code
json {   "failureOrigin" : "replication",   "internalMessage" : "Broken pipe",   "externalMessage" : "Something went wrong during replication",   "metadata" : {     "attemptNumber" : 0,     "jobId" : 8831   } }
means that during the replication (sync) process, a "Broken pipe" error occurred. In Airbyte, a "Broken pipe" typically indicates that the communication channel between processes (such as between the Airbyte worker and a connector, or between source and destination containers) was unexpectedly closed. This can happen if one of the processes crashes, is killed, or terminates before the other process finishes writing or reading data. This error is seen in multiple Airbyte issues and is often associated with: - Connector crashes or abrupt termination. - Resource exhaustion (e.g., out-of-memory or CPU limits). - Network interruptions or timeouts. - Incompatibility between connector and platform versions. For example, similar "Broken pipe" errors are reported in Airbyte when the destination process fails or is killed before the replication completes [Source PostgreSQL to S3 - Failed to convert JSON to Avro](https://github.com/airbytehq/airbyte/issues/9698), [destination-mssql] Airbyte can't create an index for _ab_cdc_* columns in mongo-source-tables](https://github.com/airbytehq/airbyte/issues/60814), and [source-snowflake reporting "No exit code found."](https://github.com/airbytehq/airbyte/issues/56456). Summary: A "Broken pipe" during replication means the data transfer between Airbyte components was interrupted, usually due to a connector or process failure. Check the logs for more details about what caused the process to terminate unexpectedly.